H&W CONTROLS
A Division of Henry & Wright Corporation
739 East 140th Street - Cleveland, OH 44110
Phone: 216-851-3750 Fax: 216-851-3970
Controls Home | Systems Info | Latest News | Drawings | Helpful Files | Contact Us

System 4000 "On-Line" Request-for-Quotation Form

If you experience any problems responding to this form, (or if you are not using a
forms-capable browser) you may email your response to: H&W Controls

If preferred... call us directly at: 216-851-3750

We will try to get your quote back to you within one to two business days.

[FrontPage Save Results Component]


Customer's Name and Address
(All info in this area must be filled in)
*Name:
*Company Name:
*Street:
*City:
*State:
*Zip:
*Phone:
  Fax:
 Email Address: (myname@somedomain.com)
*Company Type: End User OEM Rebuilder *Response Type: Email Phone Fax Postal Mail (with brochures)
System Selection SYSTEM 4000 STANDARD (9 modes of press operation, internal holding cam adjust)
SYSTEM 4001 (9 modes of press operation, external holding cam adjust from front panel)
SYSTEM 4002 (3 press modes - "Inch", "Off", "Run" (Continuous/Guard) modes only, internal cam adjust)
SYSTEM 4003 (3 press modes - "Inch", "Off", "Run" (Continuous/Guard) modes only, external cam adjust)
SYSTEM 4004 (4 press modes - "Inch", "Off", "Single" (Foot Hold-down/Foot trip) modes only, internal cam adjust)
SYSTEM 4005 (For Forging Presses) (5 press modes - Foot modes only, internal holding cam adjust, "E. Stop" and one "Inch" button on control front, motor lock-in inhibited in "Inch") 
SYSTEM 4000PBW (Press Brake/Stamping Press operation without guarding, internal cams adjust, 5 press modes)
SYSTEM 4001PBW (Press Brake/Stamping Press operation without guarding, external cams adjust, 5 press modes)
SYSTEM 4000PBG (Press Brake/Stamping Press operation for use with guarding, internal cams adjust, 5 press modes)
SYSTEM 4001PBG (Press Brake/Stamping Press operation for use with guarding, external cams adjust, 5 press modes)

Any system selection includes the Pulse Generator Assembly #550750B2 (used in place of an RLS).  Cable length:ft.


Enclosure Selection SYSTEM 400_ STANDARD (Separate enclosures for the press control and motor control, press or wall mounted)
SYSTEM 400_S (Single enclosure contains both the press control and motor control, press or wall mounted)
SYSTEM 400_C (Floor console enclosure contains press control, motor control, and press operator station)
SYSTEM 400_CC (Floor console enclosure with locking casters contains press control, motor control, and press operator station)

Press Operator Station Selection No press operator station required (customer to supply - use logic reed contacts for low voltage).
#555010A1 (STANDARD) Single operator station including: 2 guarded RUN buttons, EMERGENCY STOP button, and continuous ARMING/TOPSTOP button, in a 4x4x30" hinged-cover trough.
#555014A1 Single operator station including: 2 guarded OPTO-TOUCH (anti-fatigue) RUN buttons, EMERGENCY STOP button, and continuous ARMING/TOPSTOP button, in a 4x4x30" hinged-cover trough.
#555012A1 EMERGENCY STOP button only, installed on press control front panel (customer to supply RUN buttons).
#555013A1 EMERGENCY STOP and ARMING/TOPSTOP buttons only, installed on press control front panel (customer to supply RUN buttons).
#555011A1 Multiple operator stations*, each including: 2 guarded RUN buttons with extra contacts, EMERGENCY STOP button, continuous ARMING/TOPSTOP button, keyed ON/OFF selector, and ON indicator light, in a 4x4x30" hinged-cover trough.

* Multiple operator stations include the "Multiple Operator Station/Multiple Guard Interface Board" #554850A1A.
* Light curtains are required on each side of the press in which there are multiple operator stations installed - If all stations on one side of the press are turned off, that side becomes automatically guarded in all press modes.

Control Options: Yes No    #500230A1 Footswitch Assembly (with 8ft orange rubber sealtite cable) Yes No    #4000CUB Production Counter with keyed reset (bypassed in INCH mode) Yes No    #554700A1A Selectable "Stop Time/Minimum Safe Distance" display readout on front panel

          Yes No    #554800A1A "Crank Position" display readout on front panel (acy: ± 2° non-rev., ± 4° rev.)

          6Ch 12Ch 18Ch No   #554950A1A Die Monitoring - With Front Panel Readout Yes No 

                               #4000PED Operator station PEDESTAL/s for single or multiple stations (18" base, 35" column)
                               #554900A1A Auxiliary Cam/s with AC output (electronically adjustable from inside cabinet)*
                               #554900A1A Auxiliary Cam/s with AC output (electronically adjustable from front panel)•
                               #554900A2A Auxiliary Cam/s with DC output (electronically adjustable from inside cabinet)*
                               #554900A2A Auxiliary Cam/s with DC output (electronically adjustable from front panel)•
* Auxiliary cams are adjustable by thumbwheel switches in 1 degree increments. 1 operation per stroke each.
• Front panel cam adjustment includes the added "External Thumbwheel Switch Board" #551275A1A.

Main Motor Control: No motor control or motor operator station required (customer to interface to existing motor control).
#4000MON Motor operator station only, non-reversing, included on control front panel.*
#4000MOR Motor operator station only, reversing, included on control front panel.*
#4000MCN Complete motor control package with #4000SPN starter package, non-reversing.•
#4000MCR Complete motor control package with #4000SPR starter package, reversing.•

* Customer to interface motor operator station to existing main motor control per installation drawing.
• Complete motor control package includes adequate size enclosure, disconnect switch, fuses, heaters, control transformer, suppressors, and motor operator station mounted on control front panel.

Needed for proper starter sizing...
Motor VoltageVac.
Main Motor HorsepowerHP
Main Motor RPMRPM

Slide Adjust Motor Control: No slide motor control or motor operator station required.
#4000SOR Slide adjust operator station only, with ON/OFF keyed selector (customer to interface).
#4000SAR Complete slide adjust package with starter, heaters, and operator station on control front panel.

Needed for proper starter sizing...
Slide Motor HorsepowerHP
Slide Motor RPMRPM

Lube Motor Control: No lube motor control or motor operator station required.
#800T-Q12R Lube FAULT light only, on control front panel (customer to interface).
#4000LON Lube START and STOP buttons and FAULT light only (customer to interface).
#4000LCN Complete lube package with starter, heaters, and operator station on control front panel.

Needed for proper starter sizing...
Lube Motor HorsepowerHP
Lube Motor RPMRPM

Light Curtain Guarding:

                               Omron-STI Mini-Safe complete 3-box light curtain system with 30ft cables (includes built-in fixed and floating beam-blanking and diagnostic indicators)

Protected Height Required: 6 inches
12 inches
16 inches
20 inches
24 inches
28 inches
32 inches
36 inches
40 inches
48 inches
56 inches
60 inches

Clutch/Brake Safety Valve and Air Pressure Switch Assembly:

HERION dual safety valve includes silencer and air pressure switch adaptor (monitors both main air pressure and valve).
No clutch/brake valve required.
#XSz-16 (Input ½", output ½", exhaust ¾" NPT) with #00-164-00 silencer and #10-280-63 adaptor.
#XSz-20 (Input ½", output ¾", exhaust 1" NPT) with #00-165-00 silencer and #10-280-63 adaptor.
#XSz-32 (Input 1", output 1", exhaust 1½" NPT) with #00-166-20 silencer and #10-280-63 adaptor.
#XSz-50 (Input 1½", output 2", exhaust 2" NPT) with #00-167-20 silencer and #10-280-63 adaptor.

Additional or Special Requirements: (Multiple counters, other motor control, load monitors, etc.)

NOTE: Motor Control, Operator Station, and any other options may be prewired to the SYSTEM 4000
at no cost at our shop by customer request. Please specify lengths of sealtite required and locations of entry.

Motor control and operator station are automatically prewired to the SYSTEM 4000
when included in the same enclosure at no extra cost at our shop.

*Press Number:
*Press Strokes-Per-Minute:spm.
*Requested Delivery Date:
Area Representative:

Number of Above Control Systems: (Discount applies to last system when purchased within 1 year)

Back to Top
© H&W Controls 2000
All Rights Reserved